Midea 3 Ton Duct Type Non-Inverter AC – MHC-36CRNEUC

Installation charge AC 3.0 TON              13,500/- with a regular iron angle
Home Delivery Air Conditioner             Inside Dhaka 1500 TK. Outside Dhaka 2000TK*

Original price was: ৳ 190,000.00.Current price is: ৳ 170,000.00.

SKU: AC-001/GACW_12-2-2-4-3-4 Categories: ,

Midea 3 Ton Duct Type Non-Inverter AC – MHC-36CRNEUC

Brand: Midea
Model: MHC-36CRNEUC
Capacity: 3 Ton / 36,000 BTU/h
Type: Duct Type Air Conditioner
Technology: Non-Inverter / On-Off
Compressor: LAMDA Rotary
Refrigerant: Listed as R410
Operation: Cooling Only

Midea 3 Ton Duct Type Non-Inverter AC Price in Bangladesh – MHC-36CRNEUC

Plan discreet cooling for your commercial interior with the Midea 3 Ton Duct Type Non-Inverter AC (MHC-36CRNEUC). Featuring 36,000 BTU/h cooling capacity, a LAMDA rotary compressor, remote and wired control options, and three airflow settings, this duct-type air conditioner offers practical cooling for appropriately assessed spaces.

A ducted installation distributes cooled air through planned ductwork and outlets. This allows the indoor equipment to be incorporated into a suitable ceiling or service space while keeping visible room surfaces available for interior design.

The Midea MHC-36CRNEUC uses conventional non-inverter on-off technology and provides cooling-only operation. Its listed indoor airflow reaches 2,200 m³/h on High, with Medium and Low settings available to adjust circulation.

This model requires a 380–410V, three-phase, 50Hz electrical supply. A properly designed duct system, compatible electrical infrastructure, and adequate maintenance access are essential installation considerations.

If you are searching for the Midea 3 Ton Duct Type AC price in Bangladesh, contact Air Care Bangladesh for current pricing, availability, capacity-selection assistance, and installation quotations.

Key Features of Midea 3 Ton Duct Type Non-Inverter AC

  1. Ducted Cooling Design – Support a Discreet Interior

The Midea MHC-36CRNEUC connects to ductwork that delivers cooled air through appropriately positioned outlets.

This arrangement can complement offices, retail interiors, restaurants, and other projects where air distribution is planned alongside the interior layout.

Key Benefits:

  • Supports cooling through planned ductwork.
  • Allows air outlets to be coordinated with the interior.
  • Keeps room wall space available.
  • Suitable for projects with adequate equipment and duct clearance.

Installation requires suitable space for the indoor unit, ducts, insulation, drainage, and maintenance access.

  1. 3 Ton Capacity – 36,000 BTU/h Cooling Performance

The supplied specifications list a cooling capacity of 36,000 BTU/h, equivalent to 3 Ton.

This model can be considered for spaces where that capacity matches the calculated cooling load.

Potential Applications:

  • Office spaces.
  • Meeting and conference rooms.
  • Retail shops and showrooms.
  • Reception areas.
  • Restaurant seating areas.
  • Residential interiors with suitable duct and electrical arrangements.

Correct sizing depends on room dimensions, ceiling height, sunlight exposure, insulation, occupancy, and heat-producing equipment. Duct losses must also be considered during system design.

  1. Non-Inverter Technology – Conventional On-Off Cooling

The Midea 3 Ton Duct AC uses a non-inverter system, identified as On-Off in the supplied specifications.

The compressor cycles on and off according to cooling demand and temperature control.

Key Features:

  • Conventional on-off compressor operation.
  • Cooling-only functionality.
  • An option for customers seeking non-inverter duct equipment.
  • Remote and wired control listed in the specifications.

Actual electricity consumption depends on compressor running time, room conditions, selected settings, duct design, and installation quality.

  1. LAMDA Rotary Compressor

The supplied specifications identify a LAMDA rotary compressor for the Midea MHC-36CRNEUC.

The compressor circulates refrigerant through the system to transfer heat from the indoor space to the outdoor environment.

Key Points:

  • LAMDA compressor brand as supplied.
  • Rotary compressor configuration.
  • Non-inverter operation.
  • Cooling-only refrigeration system.
  1. Three Airflow Settings – High, Medium & Low

The Midea MHC-36CRNEUC provides the following listed indoor airflow figures:

  • High: 2,200 m³/h.
  • Medium: 1,900 m³/h.
  • Low: 1,500 m³/h.

These settings provide options for adjusting air circulation.

Advantages:

  • Higher airflow when greater circulation is needed.
  • Medium airflow for everyday operation.
  • Lower setting for reduced air delivery.
  • Flexibility to match circulation to room conditions.

Actual airflow at room outlets depends on duct length, duct size, fittings, filters, and system resistance. Confirm the unit’s available external static pressure before finalising the duct design.

  1. Sound-Level Information for Installation Planning

The supplied indoor noise figures are 57/54/52/49 dB. Since four values appear under a High/Medium/Low heading, the setting associated with each figure requires confirmation.

The listed outdoor noise level is 59.5 dB.

Planning Considerations:

  • Confirm the indoor sound rating for each operating setting.
  • Consider indoor unit placement relative to occupied rooms.
  • Assess duct and outlet design when planning room acoustics.
  • Allow for suitable mounting and vibration control.

Sound within the occupied space depends on installation, duct design, outlet selection, and operating conditions.

  1. Remote & Wired Control Options

The supplied controller specification lists Remote + Wire.

This indicates remote and wired control options for managing supported operating settings.

Advantages:

  • Convenient access to supported settings.
  • Control arrangements suited to planned interiors.
  • Practical operation when the indoor unit is concealed.
  • Flexibility in controller placement, subject to installation requirements.

Confirm which controllers and accessories are included in the quotation.

  1. Three-Phase Power Supply & Electrical Specifications

The Midea MHC-36CRNEUC requires 380–410V, three-phase, 50Hz power.

Its listed standard cooling input is 4,000 W, with a maximum input of 5,350 W.

Key Technical Details:

  • Standard cooling current: 8.2 A.
  • Maximum current: 11.7 A.
  • Standard cooling input: 4,000 W.
  • Maximum input: 5,350 W.

Confirm electrical capacity, wiring requirements, and protective devices before installation. Compressor cycling and operating conditions affect actual energy usage.

  1. Defined Duct Connections & Installation Dimensions

The indoor body dimensions are supplied as 1,400 × 700 × 245 mm, with an indoor net weight of 39.5 kg.

The table also provides the following connection dimensions:

  • Air suction opening: 1,278 × 205 mm.
  • Air discharge opening: 1,213 × 177 mm.
  • Drain connection: OD25.4.

These measurements support installation planning, but they do not replace a complete duct design.

Confirm connection orientation, mounting arrangements, external static pressure, insulation, and service clearances against the installation manual.

Why Choose Midea 3 Ton Duct Type Non-Inverter AC?

The Midea MHC-36CRNEUC combines ducted air distribution, conventional on-off cooling, and remote/wired control options for suitable interiors.

Key Advantages:

  • ✅ 3 Ton Cooling Capacity – Provides 36,000 BTU/h of listed cooling output.
  • ✅ Duct Type Design – Supports air distribution through planned ductwork.
  • ✅ Non-Inverter Operation – Conventional on-off cooling technology.
  • ✅ LAMDA Rotary Compressor – Compressor brand and type identified in the supplied specifications.
  • ✅ Three Airflow Settings – High, Medium, and Low circulation options.
  • ✅ Up to 2,200 m³/h Airflow – Listed air delivery at the High setting.
  • ✅ Remote & Wired Controls – Control options identified in the supplied table.
  • ✅ Defined Duct Openings – Connection dimensions available for planning.
  • ✅ Three-Phase Operation – Uses the specified 380–410V three-phase supply.

Midea 3 Ton Duct Type Non-Inverter AC Price in Bangladesh

Looking for the Midea MHC-36CRNEUC price in Bangladesh? This cooling-only duct air conditioner offers practical features for appropriately assessed offices, shops, meeting rooms, restaurants, and other suitable interiors.

With its 36,000 BTU/h cooling capacity, LAMDA rotary compressor, three airflow settings, and remote/wired control options, it can be evaluated against your cooling requirements and proposed duct layout.

At Air Care Bangladesh, customers can receive assistance with product selection, current pricing, stock availability, and installation planning.

Request an itemised quotation covering the AC unit, controllers, ductwork, insulation, grilles or diffusers, refrigerant piping, electrical work, drainage, and installation labour. Confirm which items are included, along with delivery arrangements and official warranty coverage.

Buy Midea MHC-36CRNEUC in Bangladesh

Air Care Limited provides air conditioner sales and related services across its service areas in Bangladesh.

Contact our team for:

  • Midea duct AC purchasing assistance.
  • AC capacity selection.
  • Installation-site assessment.
  • Duct installation planning.
  • Electrical compatibility assessment.
  • Professional installation.
  • AC servicing and cleaning.
  • Repair and maintenance.
  • Corporate purchase quotations.
  • Annual Maintenance Contract inquiries.

For the latest Midea 3 Ton Duct Type AC price in Bangladesh, contact Air Care with your location, room layout, and installation requirements.

Frequently Asked Questions (FAQs)

  1. What is the Midea 3 Ton Duct Type AC price in Bangladesh?

Contact Air Care Bangladesh for the latest quotation for the Midea MHC-36CRNEUC, including product availability and installation charges.

Ductwork and related materials should be quoted according to the site requirements.

  1. Is the MHC-36CRNEUC an inverter AC?

No. The supplied specifications identify it as non-inverter / on-off.

  1. What is its cooling capacity?

The listed cooling capacity is 36,000 BTU/h, equivalent to 3 Ton.

  1. Does this model provide heating?

No. It is specified as a cooling-only air conditioner.

  1. Which compressor does it use?

The supplied specifications identify a LAMDA rotary compressor.

  1. What refrigerant does it use?

The supplied information labels the refrigerant as R410, with a charge of 2.4 kg. Confirm the exact refrigerant designation on the unit’s nameplate before installation or servicing.

  1. How much electricity does it consume?

The listed standard cooling input is 4,000 W, with a maximum input of 5,350 W.

Actual consumption depends on compressor running time, cooling demand, room conditions, duct performance, temperature settings, and operating hours.

  1. Does this model require three-phase electricity?

Yes. The specified power supply is 380–410V, three-phase, 50Hz. Confirm that your premises have a compatible supply before ordering.

  1. What airflow and noise levels are listed?

Indoor airflow is listed as 2,200/1,900/1,500 m³/h at High, Medium, and Low settings.

The supplied indoor noise figures are 57/54/52/49 dB, but their setting mapping requires confirmation. Outdoor noise is listed as 59.5 dB.

  1. Does it support remote and wired control?

The supplied controller specification lists Remote + Wire. Confirm controller compatibility and which accessories are included in the product quotation.

  1. Can this AC cool multiple rooms?

A duct system may serve more than one area if the total cooling load, airflow requirements, duct resistance, and control arrangement are suitable.

Multiple rooms should not be assumed to have independent temperature control. A professional assessment is needed, and the unit’s external static pressure must be confirmed.

  1. What duct openings and pipe sizes are specified?

The supplied table lists:

  • Air suction opening: 1,278 × 205 mm.
  • Air discharge opening: 1,213 × 177 mm.
  • Liquid-side pipe: 3/8 inch.
  • Gas-side pipe: 5/8 inch.
  • Drain pipe: OD25.4.

Final duct sizing and installation details must follow the system design and manufacturer’s requirements.

  1. Does Air Care provide installation and servicing?

Yes. Air Care provides installation, servicing, repair, and maintenance across its service areas. Contact the team to confirm availability, work scope, and charges for your location.

Buy Midea 3 Ton Duct Type AC from Air Care Bangladesh

Choose the Midea 3 Ton Duct Type Non-Inverter AC – MHC-36CRNEUC for spaces with suitable cooling requirements, duct arrangements, and three-phase electrical supply.

Featuring 36,000 BTU/h cooling capacity, a LAMDA rotary compressor, three airflow settings, and remote/wired control options, this model brings together practical features for planned ducted cooling.

Contact Air Care Bangladesh for current pricing, product availability, and installation assistance.

Air Care – Air Conditioning Solutions

Website: https://aircare.com.bd
Hotline: 09617-225588
Email: info@aircare.com.bd

 

Specifications

MidTechnical Specifications

Specification

Details

Brand

Midea

Indoor Model

MHC-36CRNEUC

Outdoor Model

MHC-36CRNEUC

AC Type

Duct Type

Technology

Non-Inverter / On-Off

Operating Function

Cooling Only

Capacity

3 Ton

Cooling Capacity

36,000 BTU/h

Power Supply

380–410V, Three Phase, 50Hz

Compressor Type

Rotary

Listed Compressor Brand

LAMDA

Refrigerant

Listed as R410; exact designation to be confirmed

Listed Refrigerant Charge

2.4 kg

Standard Cooling Current

8.2 A

Standard Cooling Input

4,000 W

Maximum Current

11.7 A

Maximum Input

5,350 W

Listed EER — BTU/h/W

9.00

EER in W/W

Requires confirmation; supplied as 3.1 W/W

SEER

Not provided

Listed Star Rating

3 Stars; rating scheme not specified

Control

Remote + Wired; included accessories to be confirmed

Indoor Airflow — High/Medium/Low

2,200/1,900/1,500 m³/h

Listed Indoor Noise

57/54/52/49 dB; setting mapping requires confirmation

Outdoor Noise

59.5 dB

External Static Pressure

Not provided

Indoor Net Weight

39.5 kg

Indoor Gross Weight

46.5 kg

Indoor Body Dimensions — As Supplied

1,400 × 700 × 245 mm

Indoor Packing Dimensions — As Supplied

1,630 × 830 × 300 mm

Air Suction Opening

1,278 × 205 mm

Air Discharge Opening

1,213 × 177 mm

Outdoor Net Weight

68.2 kg

Outdoor Gross Weight

78.7 kg

Outdoor Body Dimensions — As Supplied

980 × 410 × 1,210 mm

Outdoor Packing Dimensions — As Supplied

1,032 × 470 × 1,280 mm

Liquid-Side Pipe Size

3/8 inch

Gas-Side Pipe Size

5/8 inch

Drain Pipe Size

OD25.4 — 25.4 mm outside diameter

Listed Temperature Range

16–32°C; range definition to be confirmed

Heating Function

Not Applicable

 

Warranty

Warranty Policy                                   Residential                                   Commercial
 
Compressor Compressor                                     05 Years                                               03 Years
 
Spare Parts Spare Parts                                      02 Years                                               01 Years
 
After-Sales Service After-Sales Service                        01 Years                                                01 Year

Delivery

Delivery Options
Installation charge AC 1-1.5 TON  Installation charge AC 3.0 TON             13,500/- with a regular iron angle
Home Delivery Air ConditionerHome Delivery Air Conditioner              Inside Dhaka 1500 TK. Outside Dhaka 2000TK*
Payment Option

, , , , , , ,

Reviews

There are no reviews yet.

Be the first to review “Midea 3 Ton Duct Type Non-Inverter AC – MHC-36CRNEUC”

Your email address will not be published. Required fields are marked *

Related Products

Shopping Cart